Gebraucht AGILENT / HP / HEWLETT-PACKARD / KEYSIGHT 8563E #9014804 zu verkaufen
URL erfolgreich kopiert!
Tippen Sie auf Zoom
ID: 9014804
Spectrum analyzer
Model number: 8565e
Options: 006, 007, 008, 8ze
Option description:
Opt. 006: 30 hz to freq. Coverage
Opt. 007: digitized fast time-domain sweeps
Opt. 008: signal identification
Key features:
Continuous 30 hz to 26.5 ghz sweeps
Resolution bandwidths of 1 hz to 100 hz digitally implemented for measurement speed
Precision timebase and 1 hz counter resolution
Adjacent channel power, channel power, carrier power and grated video measurements standard
Mil-t-28800 rugged
Frequency specifications:
Frequency range (internal mixing): 9 khz to 26.5 ghz; 30 hz to 26.5 ghz (option 006)
Frequency range (external mixing): 18 ghz to 325 ghz in 12-wave guide bands
Frequency reference accuracy:
Temperature stability: ±1 x 10-6
Aging (per year): ±1 x 10-7
Setability: ±1 x 10-8
Warmup (nominal): 5 minute ±1 x 10-7; 15 minute ±1 x 10 -8
Frequency readout accuracy (n = l0 harmonic):
Span > 2 mhz x n: ±(freq. Readout x freq. Ref. Accuracy + 5% x span + 15% x rbw + 10 hz)
Span < or = to 2 mhz x n: ±(freq. Readout x freq. Ref. Accuracy +1% x span +15% x rbw + 10 hz)
Marker count accuracy (s/n > or = to 25 db): ± (marker freq. X freq. Ref. Accuracy + 2 hz x n + 1 lsd)
Counter resolution: selectable from 1 hz to 1 mhz
Frequency span:
Range: 0 hz, 100 hz to maximum frequency
Sweep time:
Range:
Span = 0 hz: 50 µs to 6,000 s
Span > or = to 100 hz: 50 ms to 100 ks
Accuracy:
Sweep time > 30 ms: ±1% digital
Sweep time < 30 ms: ±10% analog; ±0.1% digital (option 007)
Sweep trigger: delayed, free run, single, line, video, external
Resolution bandwidth:
Range (-3 db): 1 hz to 1 mhz in a 1, 3, 10 sequence and 2 mhz
Accuracy:
1 hz to 300 khz: ±10%
1 mhz: ± 25%
2 mhz: +50%, -25%
Selectivity (-60 db/-3 db):
Rbw > or = to 300 hz: < 15:1
Rbw < or = to 100 hz: < 5:1
Video bandwidth range: 1 hz to 3 mhz in a 1, 3, 10 sequence
Noise sidebands (center frequency < or = to 1 ghz):
100 hz offset: < -18 dbc/hz
1 khz offset: < -97 dbc/hz
10 khz offset: < -113 dbc/hz
100 khz offset: < -117 dbc/hz
Residual fm (zero span): < 1 hz p-p in 20 ms; < 0.25 hz p-p in 20 ms (nominal)
Amplitude specifications:
Range: displayed average noise level to +30 dbm
Maximum safe input level:
Average continuous power: +30 dbm (1w, input atten. > or = to 10 db)
Peak pulse power (< 10 µs pulse width and < 1% duty cycle): +50 dbm (100 w, input atten. > or = to 30 db)
Dc volts: < ±0.2 v (dc-coupled)
1 db gain compression:
10 mhz to 2.9 ghz: mixer level < or = to -5 dbm
2.9 ghz to 6.5 ghz: mixer level < or = to 0 dbm
> 6.5 ghz: < or = to -3 dbm
Displayed average noise level (0 db input atten., 1 hz rbw1):
30 hz frequency: -90 dbm
1 khz frequency: -105 dbm
10 khz frequency: -120 dbm
100 khz frequency: -120 dbm
1 to 10 mhz frequency: -140 dbm
10 mhz to 2.9 ghz frequency: -149 dbm
2.9 to 6.5 ghz frequency: -148 dbm
6.5 to 13.2 ghz frequency: -145 dbm
13.2 to 22.0 ghz frequency: -149 dbm
22.0 to 26.5 ghz frequency: -139 dbm
Notes:
10 hz rbw (min. Rbw with option 103) add 10 db to noise floor
Hp 8561e only
Hp 8565e only
Hp 8563e/64e/65e only
Hp 8563e only
Hp 8564e/65e only
Except hp 8561e
For hp 8561e: -145 dbm
Toi reference to single tone
Residual responses (>200 khz, n=1): <-90 dbm
Display:
Viewing area: approx. 7 cm (v) x 9 cm (h)
Scale calibration: 10 x 10 divisions
Log scale: 10, 5, 2, 1 db per division
Linear scale: 10% of ref. Level per division
Display scale fidelity:
Log: ±0.1 db/db to a maximum of ±0.85 db, 0 to -90 db; maximum of ±1.5 db, 0 to -100 db (rbw < or = to 100 hz)
Linear: ±3% of reference level
Reference level range: log = -120 to +30 dbm in 0.1 db steps; linear = 2.2 µv to 7.07 v in 1% steps
Frequency response, relative (10 db input attenuation):
Frequency:
100 mhz to 2.0 ghz: ±1.0 db
30 hz to 2.9 ghz: ±1.25 db
2.9 ghz to 6.5 ghz: ±1.5 db
6.5 ghz to 13.2 ghz: ±2.2 db
13.2 ghz to 22.0 ghz: ±2.5 db
22.0 ghz to 26.5 ghz: ±3.3 db
Calibrator output: 300 mhz x (1 ±freq. Ref. Acc'y), -10 dbm: < ±0.3 db
Input attenuator:
Range: 0 to 70 db in 10 db steps
Switching uncertainty (ref. To 10 db, 30 hz to 2.9 ghz): < ±0.6 db/10 db step, ±1.8 db max.
Repeatability: ±0.1 db (nominal)
If gain uncertainty (10 db atten., 0 to -80 dbm ref. Level): < ±1 db
Resolution bandwidth switching uncertainty: < ±0.5 db
Pulse digitization uncertainty (pulse response mode, prf > or = to 720/sweep time, rbw < or = to 1 mhz): < 1.25 db pk-pk (log); 4% of reference level pk-pk (linear)
Accuracy (from gate trigger input to pos. Edge of gate output): < ±1 µs
Gate length:
Range: 1 µs to 65.535 µs
Resolution: 1 µs
Accuracy (from pos. Edge to neg. Edge of gate output): < ±1 µs
Delayed sweep specifications:
Trigger modes: free run, line, external, video
Range: 2 µs to 65.535 µs, option 007, sweeptime < 30 µs; -9.9 µs to +65.535 µs; sweeptime > or = to 30 µs, +2 µs to 65.535 µs
Resolution: 1 µs
Accuracy: ±1 µs
Demodulation (spectrum) specifications:
Modulation type: am and fm
Audio output: speaker and phone jack with volume control
Inputs and outputs (all values nominal) specifications:
Front panel connectors:
Rf input (50 ω): type-n female
Vswr (> or = to 10 db atten.): < 1.5:1 below 2.9 ghz; < 2.3:1 > or = to 2.9 ghz
Lo emission level (average with 10 db atten): < - 80 dbm
Second if input (sma female, 50 ω):
Frequency: 310.7 mhzfull screen level: -30 dbm
Gain compression: -20 dbm
First lo output (sma female, 50 ω):
Frequency: 3.0 to 6.8107 ghz
Amplitude: +16.5 dbm ±2 db
Cal output: bnc female, 50 ω
Probe power: +15 vdc, -12.6 vdc, and gnd (150 ma maximum each)
Rear panel connectors:
10 mhz reference in/out (shared bnc female, 50 ω):
Output frequency accuracy: 10 mhz ±(10 x mhz freq. Ref. Acc'y)
Output amplitude: 0 dbm
Input amplitude: -2 to +10 dbm
Video output (bnc, 50 ω):
Amplitude (rbw > or = to 300 hz): 0 to +1 v full scale
Lo sweep i fav output (shared bnc female, 2 kω):
Amplitude (lo sweep): 0 to 10 v, no load
Blanking/gate output: shared bnc female, 50 ω, ttl output
External/gate trigger input (shared bnc female, > 10 kω): settable to high ttl or low ttl
Hp-ib: ieee-488 bus connector
Interface functions: sh1, ah1, t6, l4, sr1, rl1, pp0, dc1, dt0, c1, c28, e1
General specifications:
Environmental:
Military specs: per mil-t-28800
Calibration interval: two years
Warmup time: 5 minutes in ambient conditions
Temperature: -10°c to +55°c (operating); -51° to +71°c (non operating)
Humidity: 95% @ 40°c for five days
Rain resistance: drip-proof at 16 liters/hour/sq. Ft.
Altitude: 15,000 ft. (operating); 50,000 ft. (non operating)
Pulse shock (half sine): 30 g for 11 ms duration
Transit drop: 8-inch drop on six faces and eight corners
Electromagnetic compatibility: conducted and radiated interference in compliance with cispr pub. 11 (1990). Meets mil-std-461c, part 4, with certain exceptions.
Power requirements:
115 vac operation: 90 to 140 v rms, 3.2 a rms max., 47 to 440 hz
230 vac operation: 180 to 250 v rms, 1.8 a rms max., 47 to 66 hz
Maximum power dissipation: 180 w
Audible noise (nominal): < 5.0 bels power at room temp. (iso dp7779)
Size (w/o handle, feet, cover): 337 mm w x 187 mm h x 460 mm d (13 1/4" x 7 3/8" x 18 1/8")
Weight (carrying, nominal): 20 kg (44 lb).
AGILENT/HP/HEWLETT-PACKARD/KEYSIGHT 8563E ist eine leistungsstarke elektronische Test- und Messausrüstung, die den Anforderungen von Konstruktions- und Fertigungsingenieuren gerecht wird. Es verfügt über eine hochauflösende Kombination aus einem Spektrumanalysator und einem Netzwerkanalysator in einem Instrument, die eine präzise Analyse und Fehlerbehebung von analogen, digitalen und HF-Schaltungen ermöglicht. Das 15,6-Zoll-HD-Display des HP 8563E bietet präzise Klarheit und erleichtert die Arbeit mit häufig verwendeten Test- und Messanwendungen. AGILENT 8563E ist ideal für Anwender, die eine breite Palette von Fähigkeiten von einem einzigen Instrument benötigen. Es verfügt über einen Standard-Frequenzbereich von 10 Hz bis 3,6 GHz und ist in der Lage, eine breite Palette von Parametern zu messen, einschließlich Gleichstrom (DC) -Parameter, Frequenzgang und Störsignale. KEYSIGHT 8563E verfügt zudem über leistungsstarke Analysefunktionen wie Rauschzahl, harmonische Analyse, Rücklaufverlust und Impedanzmessungen. Dies macht es zu einem vielseitigen Tool für Anwendungen wie EMV, optische, Audio- und Videotests. HEWLETT-PACKARD 8563E hat eine maximale Sweep-Geschwindigkeit von 10 ms und gibt ihm die Geschwindigkeit und Genauigkeit, die für die meisten Anwendungen benötigt wird. Es enthält auch eine Vielzahl von nützlichen Funktionen für einen effizienten Betrieb, wie eine mehrsprachige Anzeige, sowie ein integriertes Gleichungslösungs- und Mathematik-Paket. Darüber hinaus ist 8563E mit einer umfassenden Palette automatisierter Tests ausgestattet, um den Gerätebetrieb an festgelegten Grenzen in Produktionstests schnell zu überprüfen. Dies ermöglicht es Benutzern, Zeit zu sparen und den Testprozess zu rationalisieren. AGILENT/HP/HEWLETT-PACKARD/KEYSIGHT 8563E ist für die einfache Integration in automatisierte Testsysteme und Produktionslinien konzipiert und mit dem LabView Softwarepaket kompatibel. HP 8563E ist ein zuverlässiges und robustes Prüf- und Messgerät. Es arbeitet mit einem einzigen + 5V Gleichstromnetzteil und erfüllt die meisten MIL-STDs in Abschirmung und elektrostatischer Entladung. Darüber hinaus erfüllt es die UL- und CE-Normen, die für Sicherheit, elektromagnetische Verträglichkeit und Hochfrequenzstrahlenschutz erforderlich sind. AGILENT 8563E ist eine leistungsstarke und zuverlässige elektronische Test- und Messgerätelösung für Konstruktions-, Entwicklungs- und Fertigungsteams. Das 15,6-Zoll-HD-Display, vielseitige Analysefunktionen, automatisierte Tests und einfache Integration machen es zu einer ausgezeichneten Wahl für eine Vielzahl von Anwendungen.
Es liegen noch keine Bewertungen vor