Gebraucht AGILENT / HP / HEWLETT-PACKARD / KEYSIGHT 8563E #9014804 zu verkaufen

ID: 9014804
Spectrum analyzer Model number: 8565e Options: 006, 007, 008, 8ze Option description: Opt. 006: 30 hz to freq. Coverage Opt. 007: digitized fast time-domain sweeps Opt. 008: signal identification Key features: Continuous 30 hz to 26.5 ghz sweeps Resolution bandwidths of 1 hz to 100 hz digitally implemented for measurement speed Precision timebase and 1 hz counter resolution Adjacent channel power, channel power, carrier power and grated video measurements standard Mil-t-28800 rugged Frequency specifications: Frequency range (internal mixing): 9 khz to 26.5 ghz; 30 hz to 26.5 ghz (option 006) Frequency range (external mixing): 18 ghz to 325 ghz in 12-wave guide bands Frequency reference accuracy: Temperature stability: ±1 x 10-6 Aging (per year): ±1 x 10-7 Setability: ±1 x 10-8 Warmup (nominal): 5 minute ±1 x 10-7; 15 minute ±1 x 10 -8 Frequency readout accuracy (n = l0 harmonic): Span > 2 mhz x n: ±(freq. Readout x freq. Ref. Accuracy + 5% x span + 15% x rbw + 10 hz) Span < or = to 2 mhz x n: ±(freq. Readout x freq. Ref. Accuracy +1% x span +15% x rbw + 10 hz) Marker count accuracy (s/n > or = to 25 db): ± (marker freq. X freq. Ref. Accuracy + 2 hz x n + 1 lsd) Counter resolution: selectable from 1 hz to 1 mhz Frequency span: Range: 0 hz, 100 hz to maximum frequency Sweep time: Range: Span = 0 hz: 50 µs to 6,000 s Span > or = to 100 hz: 50 ms to 100 ks Accuracy: Sweep time > 30 ms: ±1% digital Sweep time < 30 ms: ±10% analog; ±0.1% digital (option 007) Sweep trigger: delayed, free run, single, line, video, external Resolution bandwidth: Range (-3 db): 1 hz to 1 mhz in a 1, 3, 10 sequence and 2 mhz Accuracy: 1 hz to 300 khz: ±10% 1 mhz: ± 25% 2 mhz: +50%, -25% Selectivity (-60 db/-3 db): Rbw > or = to 300 hz: < 15:1 Rbw < or = to 100 hz: < 5:1 Video bandwidth range: 1 hz to 3 mhz in a 1, 3, 10 sequence Noise sidebands (center frequency < or = to 1 ghz): 100 hz offset: < -18 dbc/hz 1 khz offset: < -97 dbc/hz 10 khz offset: < -113 dbc/hz 100 khz offset: < -117 dbc/hz Residual fm (zero span): < 1 hz p-p in 20 ms; < 0.25 hz p-p in 20 ms (nominal) Amplitude specifications: Range: displayed average noise level to +30 dbm Maximum safe input level: Average continuous power: +30 dbm (1w, input atten. > or = to 10 db) Peak pulse power (< 10 µs pulse width and < 1% duty cycle): +50 dbm (100 w, input atten. > or = to 30 db) Dc volts: < ±0.2 v (dc-coupled) 1 db gain compression: 10 mhz to 2.9 ghz: mixer level < or = to -5 dbm 2.9 ghz to 6.5 ghz: mixer level < or = to 0 dbm > 6.5 ghz: < or = to -3 dbm Displayed average noise level (0 db input atten., 1 hz rbw1): 30 hz frequency: -90 dbm 1 khz frequency: -105 dbm 10 khz frequency: -120 dbm 100 khz frequency: -120 dbm 1 to 10 mhz frequency: -140 dbm 10 mhz to 2.9 ghz frequency: -149 dbm 2.9 to 6.5 ghz frequency: -148 dbm 6.5 to 13.2 ghz frequency: -145 dbm 13.2 to 22.0 ghz frequency: -149 dbm 22.0 to 26.5 ghz frequency: -139 dbm Notes: 10 hz rbw (min. Rbw with option 103) add 10 db to noise floor Hp 8561e only Hp 8565e only Hp 8563e/64e/65e only Hp 8563e only Hp 8564e/65e only Except hp 8561e For hp 8561e: -145 dbm Toi reference to single tone Residual responses (>200 khz, n=1): <-90 dbm Display: Viewing area: approx. 7 cm (v) x 9 cm (h) Scale calibration: 10 x 10 divisions Log scale: 10, 5, 2, 1 db per division Linear scale: 10% of ref. Level per division Display scale fidelity: Log: ±0.1 db/db to a maximum of ±0.85 db, 0 to -90 db; maximum of ±1.5 db, 0 to -100 db (rbw < or = to 100 hz) Linear: ±3% of reference level Reference level range: log = -120 to +30 dbm in 0.1 db steps; linear = 2.2 µv to 7.07 v in 1% steps Frequency response, relative (10 db input attenuation): Frequency: 100 mhz to 2.0 ghz: ±1.0 db 30 hz to 2.9 ghz: ±1.25 db 2.9 ghz to 6.5 ghz: ±1.5 db 6.5 ghz to 13.2 ghz: ±2.2 db 13.2 ghz to 22.0 ghz: ±2.5 db 22.0 ghz to 26.5 ghz: ±3.3 db Calibrator output: 300 mhz x (1 ±freq. Ref. Acc'y), -10 dbm: < ±0.3 db Input attenuator: Range: 0 to 70 db in 10 db steps Switching uncertainty (ref. To 10 db, 30 hz to 2.9 ghz): < ±0.6 db/10 db step, ±1.8 db max. Repeatability: ±0.1 db (nominal) If gain uncertainty (10 db atten., 0 to -80 dbm ref. Level): < ±1 db Resolution bandwidth switching uncertainty: < ±0.5 db Pulse digitization uncertainty (pulse response mode, prf > or = to 720/sweep time, rbw < or = to 1 mhz): < 1.25 db pk-pk (log); 4% of reference level pk-pk (linear) Accuracy (from gate trigger input to pos. Edge of gate output): < ±1 µs Gate length: Range: 1 µs to 65.535 µs Resolution: 1 µs Accuracy (from pos. Edge to neg. Edge of gate output): < ±1 µs Delayed sweep specifications: Trigger modes: free run, line, external, video Range: 2 µs to 65.535 µs, option 007, sweeptime < 30 µs; -9.9 µs to +65.535 µs; sweeptime > or = to 30 µs, +2 µs to 65.535 µs Resolution: 1 µs Accuracy: ±1 µs Demodulation (spectrum) specifications: Modulation type: am and fm Audio output: speaker and phone jack with volume control Inputs and outputs (all values nominal) specifications: Front panel connectors: Rf input (50 ω): type-n female Vswr (> or = to 10 db atten.): < 1.5:1 below 2.9 ghz; < 2.3:1 > or = to 2.9 ghz Lo emission level (average with 10 db atten): < - 80 dbm Second if input (sma female, 50 ω): Frequency: 310.7 mhzfull screen level: -30 dbm Gain compression: -20 dbm First lo output (sma female, 50 ω): Frequency: 3.0 to 6.8107 ghz Amplitude: +16.5 dbm ±2 db Cal output: bnc female, 50 ω Probe power: +15 vdc, -12.6 vdc, and gnd (150 ma maximum each) Rear panel connectors: 10 mhz reference in/out (shared bnc female, 50 ω): Output frequency accuracy: 10 mhz ±(10 x mhz freq. Ref. Acc'y) Output amplitude: 0 dbm Input amplitude: -2 to +10 dbm Video output (bnc, 50 ω): Amplitude (rbw > or = to 300 hz): 0 to +1 v full scale Lo sweep i fav output (shared bnc female, 2 kω): Amplitude (lo sweep): 0 to 10 v, no load Blanking/gate output: shared bnc female, 50 ω, ttl output External/gate trigger input (shared bnc female, > 10 kω): settable to high ttl or low ttl Hp-ib: ieee-488 bus connector Interface functions: sh1, ah1, t6, l4, sr1, rl1, pp0, dc1, dt0, c1, c28, e1 General specifications: Environmental: Military specs: per mil-t-28800 Calibration interval: two years Warmup time: 5 minutes in ambient conditions Temperature: -10°c to +55°c (operating); -51° to +71°c (non operating) Humidity: 95% @ 40°c for five days Rain resistance: drip-proof at 16 liters/hour/sq. Ft. Altitude: 15,000 ft. (operating); 50,000 ft. (non operating) Pulse shock (half sine): 30 g for 11 ms duration Transit drop: 8-inch drop on six faces and eight corners Electromagnetic compatibility: conducted and radiated interference in compliance with cispr pub. 11 (1990). Meets mil-std-461c, part 4, with certain exceptions. Power requirements: 115 vac operation: 90 to 140 v rms, 3.2 a rms max., 47 to 440 hz 230 vac operation: 180 to 250 v rms, 1.8 a rms max., 47 to 66 hz Maximum power dissipation: 180 w Audible noise (nominal): < 5.0 bels power at room temp. (iso dp7779) Size (w/o handle, feet, cover): 337 mm w x 187 mm h x 460 mm d (13 1/4" x 7 3/8" x 18 1/8") Weight (carrying, nominal): 20 kg (44 lb).
AGILENT/HP/HEWLETT-PACKARD/KEYSIGHT 8563E ist eine leistungsstarke elektronische Test- und Messausrüstung, die den Anforderungen von Konstruktions- und Fertigungsingenieuren gerecht wird. Es verfügt über eine hochauflösende Kombination aus einem Spektrumanalysator und einem Netzwerkanalysator in einem Instrument, die eine präzise Analyse und Fehlerbehebung von analogen, digitalen und HF-Schaltungen ermöglicht. Das 15,6-Zoll-HD-Display des HP 8563E bietet präzise Klarheit und erleichtert die Arbeit mit häufig verwendeten Test- und Messanwendungen. AGILENT 8563E ist ideal für Anwender, die eine breite Palette von Fähigkeiten von einem einzigen Instrument benötigen. Es verfügt über einen Standard-Frequenzbereich von 10 Hz bis 3,6 GHz und ist in der Lage, eine breite Palette von Parametern zu messen, einschließlich Gleichstrom (DC) -Parameter, Frequenzgang und Störsignale. KEYSIGHT 8563E verfügt zudem über leistungsstarke Analysefunktionen wie Rauschzahl, harmonische Analyse, Rücklaufverlust und Impedanzmessungen. Dies macht es zu einem vielseitigen Tool für Anwendungen wie EMV, optische, Audio- und Videotests. HEWLETT-PACKARD 8563E hat eine maximale Sweep-Geschwindigkeit von 10 ms und gibt ihm die Geschwindigkeit und Genauigkeit, die für die meisten Anwendungen benötigt wird. Es enthält auch eine Vielzahl von nützlichen Funktionen für einen effizienten Betrieb, wie eine mehrsprachige Anzeige, sowie ein integriertes Gleichungslösungs- und Mathematik-Paket. Darüber hinaus ist 8563E mit einer umfassenden Palette automatisierter Tests ausgestattet, um den Gerätebetrieb an festgelegten Grenzen in Produktionstests schnell zu überprüfen. Dies ermöglicht es Benutzern, Zeit zu sparen und den Testprozess zu rationalisieren. AGILENT/HP/HEWLETT-PACKARD/KEYSIGHT 8563E ist für die einfache Integration in automatisierte Testsysteme und Produktionslinien konzipiert und mit dem LabView Softwarepaket kompatibel. HP 8563E ist ein zuverlässiges und robustes Prüf- und Messgerät. Es arbeitet mit einem einzigen + 5V Gleichstromnetzteil und erfüllt die meisten MIL-STDs in Abschirmung und elektrostatischer Entladung. Darüber hinaus erfüllt es die UL- und CE-Normen, die für Sicherheit, elektromagnetische Verträglichkeit und Hochfrequenzstrahlenschutz erforderlich sind. AGILENT 8563E ist eine leistungsstarke und zuverlässige elektronische Test- und Messgerätelösung für Konstruktions-, Entwicklungs- und Fertigungsteams. Das 15,6-Zoll-HD-Display, vielseitige Analysefunktionen, automatisierte Tests und einfache Integration machen es zu einer ausgezeichneten Wahl für eine Vielzahl von Anwendungen.
Es liegen noch keine Bewertungen vor