Gebraucht TERADYNE Catalyst #149653 zu verkaufen

TERADYNE Catalyst
Hersteller
TERADYNE
Modell
Catalyst
ID: 149653
Tester Configuration: 2 processor system Processor 1: 450 MHz sparcv9 (online) Processor 3: 450 MHz sparcv9 (online) PCI based system Terabus is present TCI is present CATALYST_TH 1 BACKPLANE A #Slot Type Num XptA XptB Name 2 879-858-35 0 # 23 24 PLFD CC 3 879-858-25 0 # 21 22 PLFS CC 4 949-694-51 0 # 19 20 OVI CC 5 879-792-01 0 # 17 18 TIME CC 6 879-857-01 0 # 15 16 PMM CC-01 7 000-000-00 0 # 13 14 EMPTY 8 879-858-35 0 # 11 12 PLFD CC 9 000-000-00 0 # 9 10 EMPTY 10 949-681-50 0 # 7 8 VHFAWG400 DIFF CC 11 949-672-50 0 # 5 6 VHFDIG CC 14 879-858-35 0 # 25 26 PLFD CC 15 949-672-50 0 # 27 28 VHFDIG CC 16 000-000-00 0 # 29 30 EMPTY 17 000-000-00 0 # 31 32 EMPTY 18 949-643-00 0 # 33 34 TJD CC 19 949-838-20 0 # 35 36 WF (BBAC) CC 20 000-000-00 0 # 37 38 EMPTY 21 949-694-51 0 # 39 40 OVI CC 22 879-858-25 0 # 41 42 PLFS CC 23 879-858-35 0 # 43 44 PLFD CC 1 949-669-00 0 # 3 0 HAS (Left HAS LA669-00) 13 949-668-00 0 # 0 0 CATALYST HAC 12 949-667-00 0 # 0 0 DIF 24 949-669-01 0 # 4 0 HAS (Right HAS LA669-01) END RF_PIPES 1 # pipe-name slot schan description END # # Up to 4 Precision AC Card Cages are allowed # PRECISION_AC 1 #Slot Type Num Name 1 949-718-00 0 # PLFDIG TCI 2 879-764-01 0 # PLFSRC 3 879-779-00 0 # 1M SMEM 4 949-664-00 0 # VHFDIG MF 5 949-827-00 0 # VHFAWG 6 949-664-00 0 # VHFDIG MF 7 000-000-00 0 # EMPTY 8 949-671-00 0 # PACS CAGE INT END PRECISION_AC 2 #Slot Type Num Name 1 949-718-00 0 # PLFDIG TCI 2 879-764-01 0 # PLFSRC 3 879-779-00 0 # 1M SMEM 4 949-718-00 0 # PLFDIG TCI 5 949-718-00 0 # PLFDIG TCI 6 949-840-01 0 # WF (BBAC) 7 000-000-00 0 # EMPTY 8 949-671-00 0 # PACS CAGE INT END # # Up to 8 Universal Backplane/Synch Power Subsystem # cages are allowed # # For the Synch Power Subsystem: # Slot Type Name Instr1 # Instr2 # Ammeter # # # Instr1 # - insrument connected to the first two matrix lines # Instr2 # - insrument connected to the last two matrix lines # Ammeter # - ammeter connection # to AVOID errors, put NO 0 if no instrument is connected. # # UB_SPS_CAGE 1 # Slot Type Num Name 1 879-802-02 0 # UB_SPS_802 2 517-301-00 0 # UB_APU 3 517-301-00 0 # UB_APU 4 517-301-00 0 # UB_APU 5 517-301-00 0 # UB_APU 6 517-301-00 0 # UB_APU 7 517-301-00 0 # UB_APU 8 517-301-00 0 # UB_APU 9 517-301-00 0 # UB_APU 10 517-301-00 0 # UB_APU 11 517-301-00 0 # UB_APU 12 517-301-00 0 # UB_APU 13 517-301-00 0 # UB_APU 14 879-925-01 0 # UB_60_V_SRC MAT 1 15 879-925-01 0 # UB_60_V_SRC DUT 1 16 879-925-01 0 # UB_60_V_SRC MAT 2 17 879-925-01 0 # UB_60_V_SRC MAT 3 18 879-925-01 0 # UB_60_V_SRC MAT 5 19 879-925-01 0 # UB_60_V_SRC DUT 5 21 879-690-00 0 # UB_ASY 22 517-300-01 0 # UB_TJ300 END UB_SPS_CAGE 2 # Slot Type Num Name 1 879-802-02 0 # UB_SPS_802 2 949-700-01 0 # UB_OVI_CAL 1 3 949-693-01 0 # UB_OVI_CTRL 21 4 ?? ?? 4 949-698-01 0 # UB_OVI_AM 1 5 949-698-01 0 # UB_OVI_AM 2 6 949-698-01 0 # UB_OVI_AM 3 7 949-698-01 0 # UB_OVI_AM 4 22 517-300-01 0 # UB_TJ300 END HSD100_CHAN_CAGE 1 #Slot Type Num Fld1 Fld2 Name 1 949-921-01 0 # HSD CDM 400 2 949-921-01 0 # HSD CDM 400 3 949-921-01 0 # HSD CDM 400 4 949-921-01 0 # HSD CDM 400 5 949-820-10 0 # HSD CSB 6 949-921-01 0 # HSD CDM 400 7 949-921-01 0 # HSD CDM 400 8 949-921-01 0 # HSD CDM 400 9 949-921-01 0 # HSD CDM 400 END HSD100_CHAN_CAGE 2 #Slot Type Num Fld1 Fld2 Name 1 949-921-01 0 # HSD CDM 400 2 949-921-01 0 # HSD CDM 400 3 949-921-01 0 # HSD CDM 400 4 949-921-01 0 # HSD CDM 400 5 949-820-00 0 # HSD CSB 6 949-921-01 0 # HSD CDM 400 7 949-921-01 0 # HSD CDM 400 8 949-921-01 0 # HSD CDM 400 9 949-921-01 0 # HSD CDM 400 END HSD100_CHAN_CAGE 3 #Slot Type Num Fld1 Fld2 Name 1 949-921-01 0 # HSD CDM 400 2 949-921-01 0 # HSD CDM 400 3 949-921-01 0 # HSD CDM 400 4 949-921-01 0 # HSD CDM 400 5 949-820-00 0 # HSD CSB END CATALYST_TH 1 BACKPLANE B #Slot Type Num Name 25 949-625-00 0 # HSD DTH 26 949-625-00 0 # HSD DTH 27 949-625-00 0 # HSD DTH 28 949-625-00 0 # HSD DTH 29 949-626-10 0 # HSD THS 30 949-625-00 0 # HSD DTH 31 949-625-00 0 # HSD DTH 32 949-625-00 0 # HSD DTH 33 949-625-00 0 # HSD DTH 34 949-625-00 0 # HSD DTH 35 949-625-00 0 # HSD DTH 36 949-625-00 0 # HSD DTH 37 949-625-00 0 # HSD DTH 38 949-626-10 0 # HSD THS 39 949-625-00 0 # HSD DTH 40 949-625-00 0 # HSD DTH 41 949-625-00 0 # HSD DTH 42 949-625-00 0 # HSD DTH 43 949-625-00 0 # HSD DTH 44 949-625-00 0 # HSD DTH 45 949-625-00 0 # HSD DTH 46 949-625-00 0 # HSD DTH 47 949-626-20 0 # HSD THS/HCLK 48 949-625-00 0 # HSD DTH 49 949-625-00 0 # HSD DTH 50 949-625-00 0 # HSD DTH 51 949-625-00 0 # HSD DTH 61 949-625-00 0 # HSD DTH 62 949-625-00 0 # HSD DTH 63 949-625-00 0 # HSD DTH 64 949-625-00 0 # HSD DTH 65 949-626-00 0 # HSD THS 66 949-625-00 0 # HSD DTH 67 949-625-00 0 # HSD DTH 68 949-625-00 0 # HSD DTH 69 949-625-00 0 # HSD DTH 70 949-625-00 0 # HSD DTH 71 949-625-00 0 # HSD DTH 72 949-625-00 0 # HSD DTH 73 949-625-00 0 # HSD DTH 74 949-626-10 0 # HSD THS 75 949-625-00 0 # HSD DTH 76 949-625-00 0 # HSD DTH 77 949-625-00 0 # HSD DTH 78 949-625-00 0 # HSD DTH END # # Trigger Switch Yard # # Note: The logical slot numbers below correspond to the physical slot # numbers only for test systems which contain a TSY card # cage. In test systems which contain an SCS/TSY card cage the # mapping is: # # Logical TSY slot (below) Physical slot # 1 -> 2 # 3 -> 1 # TSY CAGE #Slot Type Num Name 1 879-655-02 0 # TSY 2 000-000-00 0 # EMPTY 3 879-671-01 0 # T_DELAY 4 000-000-00 0 # EMPTY END # # Time Subsystem # TIME_SUBSYSTEM # Board ID Serial # Name 879-793-00 # TMS Timer 879-794-01 # TMS Counter 879-795-01 # TMS Support END # # DC Subsystem - # # SRC <NUM> [1 - 13] # (sources 1-5 are MATRIX sources 1-5 # sources 6-13 are DUT sources 1-8) # HCU <NUM> *[1 - 4] # REF HCU <NUM> *[1 - 4] # HVSRC <NUM> *[1 - 4] # PWRSRC <NUM> [1 - 4] # DATABITS <NUM> - <NUM> [1 - 192] # # ** These instruments share the same seven-slot cage -- only one # instrument is allowed per slot. # DC_SUBSYSTEM # UBVI 60 1 ( 60V V/I Source in Universal Backplane 1 : slot 14) # UBVI 60 2 ( 60V V/I Source in Universal Backplane 1 : slot 16) # UBVI 60 3 ( 60V V/I Source in Universal Backplane 1 : slot 17) HCU 4 # UBVI 60 5 ( 60V V/I Source in Universal Backplane 1 : slot 18) # UBVI 60 6 ( 60V V/I Source in Universal Backplane 1 : slot 15) HCU 7 HCU 8 HCU 9 # UBVI 60 10 ( 60V V/I Source in Universal Backplane 1 : slot 19) DATABITS 1 - 48 # UB_MATRIX # # Testhead 1 # XPTs UB Cage Slot Type # 1-4 1 2 APU # 5-8 1 3 APU # 9-12 1 4 APU # 13-16 1 5 APU # 17-20 1 6 APU # 21-24 1 7 APU # 25-28 1 8 APU # 29-32 1 9 APU # 33-36 1 10 APU # 37-40 1 11 APU # 41-44 1 12 APU # 45-48 1 13 APU END.
TERADYNE Catalyst ist eine Endprüfanlage von TERADYNE, einem der weltweit führenden Anbieter von automatischen Testgeräten (ATE). Katalysator bietet Hochdurchsatz-Testlösungen für die Automobil-, Industrie- und Konsumgerätehersteller. Das System ist in der Lage, elektrische, optische, akustische und thermische Leistungen zu testen. TERADYNE Catalyst nutzt eine skalierbare Architektur, die für maximale Verfügbarkeit und niedrige Betriebskosten konzipiert ist. Zu den Hauptmerkmalen des Katalysators zählen seine Flexibilität und Erweiterbarkeit. Es wurde mit einer hochkonfigurierbaren Plattform entwickelt, die mit Automatisierung, Robotik und Datenerfassung programmiert und angepasst werden kann. Seine Multi-Site, Multi-Level-Testfunktionen sind ideal für die Prüfung einer großen Anzahl von Produktdesigns. Darüber hinaus ermöglicht TERADYNE Catalyst eine verbesserte Testabdeckung mit benutzerkonfigurierbaren Testprogrammen, die mehrere Module, Vertikale und Sprachen umfassen. Catalyst bietet auch eine Reihe fortgeschrittener Funktionen wie erweitertes Debugging, schnelles Inbetriebnehmen der Produktion, Sample-in-Place-Tests (SiP), Echtzeit-Datenerfassung und -analyse, Hochgeschwindigkeits-Fixture-Switching und Automatisierungsfunktionen. Darüber hinaus verfügt TERADYNE Catalyst über eine fortschrittliche Plattform, die Konfigurationen mehrerer Einheiten je nach Anwendungsbedarf des Benutzers ermöglicht. Neben seinen Eigenschaften ist Catalyst auch sehr zuverlässig. Seine verbesserten Vorrichtungen, Behälter und Adapter sind für maximale Langlebigkeit und Haltbarkeit ausgelegt. Darüber hinaus verringern die eingebauten Sicherheitsfunktionen das Risiko von Ausfällen, die kostspielige Ausfallzeiten verursachen können. Die überlegene Leistung, Zuverlässigkeit und Skalierbarkeit von TERADYNE Catalyst machen es zu einer geeigneten Wahl für die anspruchsvollsten Testanwendungen. Es kann einfach in rauen Umgebungen betrieben werden und entspricht den komplexesten Standards und Spezifikationen. Zusammenfassend ist Catalyst eine hochmoderne Endprüfmaschine mit vielen fortschrittlichen Funktionen für optimierte Leistung und außergewöhnliche Zuverlässigkeit. Seine Skalierbarkeit und Flexibilität machen es zu einer idealen Wahl für jede Branche, und seine überlegenen Sicherheitsfunktionen gewährleisten ein hohes Maß an Produktintegrität und Wert.
Es liegen noch keine Bewertungen vor